Save my name, email, and website in this browser for the next time I comment. SPRINKLER HEAD UPRIGHT & PENDENT TYPE NV003 to NV006 Nittan reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Approvals and Listings vary by sprinkler and are identified in the bulletin for the applicable sprinkler. Penempatan Sprinkler Pendent dan Sprinkler Upright yang benarakan membuat aliran dalam jaringan instalasi fire sprinkle berjalan dengan baik, pancaran air dari pipa akan maksimal dalam memadamkan kebakaran yang terjadi di area tersebut. Alibaba.com offers 1,735 upright type sprinkler products. Upright sprinkler heads project up into a space and have deflectors that spray the water downwards. For example, a head that you attach to your hose may protrude off of the ground anywhere from a few inches to a foot or more. sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). We are a leading manufacturer and supplier of different equipments used in fire fighting such as Upright Type Sprinkler. The exact size depends on the type of sprinkler head that you buy. A wide variety of fire sprinkler upright type options are available to you, such as type. Rev.0 Features • 1/2 inch Connection Thread • K-5.6 (80) It is used on dry pipe systems that are exposed to freezing temperatures or seasonably drained to avoid freezing. Upright Sprinkler Heads Stands upright Sprays water upward in a hemispherical pattern Useful in buildings with exposed ceilings like mechanical rooms or hard to reach places like beams and ducts Side Wall Sprinkler Heads The temperature response is standard response (5mm glass bulb) and quick response (3mm glass bulb). They also provide a circle spray pattern while sprinkling the water and thus, covers all the area. Upright sprinklers are used mostly in places where obstructions may block water spray during a fire, and their height allows them to aim water around possible obstacles. Your email address will not be published. Upright type, design incorporates state-of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, precise operation. Sort by type, style, k-factor, pressure and more. Side wall sprinkler heads stand out from a wall and have a deflector that sprays water away from the wall in a half-circle spray pattern. Fire Fighting - Pendent sprinkler vs Upright sprinkler Details with AutoCad drawing Similar information on bubblers is found … Continue reading Selecting the Right Sprinkler Head → They are designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls. Upright sprinkler heads project up into a space and have deflectors that spray the water downwards. About 0% of these are Garden Sprinklers. Upright type, design incorporates state-of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, precise operation. With With a 14.0 (202 metric*) nominal K-Factor and special deflector, this sprinkler produces large, high-momentum water droplets in a hemispheric pattern below the deflector. Upright sprinkler heads work well in areas with obstructions, exposed ceilings, or hard to reach places like beams and ducts. Upright Sprinkler Head. Upright Type Sprinkler. (9,5 to 19,0 With a 14.0 (202 metric*) nominal K-Factor and special deflector, this sprinkler produces large, high-momentum water droplets in a hemispheric pattern below the deflector. The exact size depends on the type of sprinkler head that you buy. One downside is that the pipeline in an upright sprinkler can become an obstacle in itself to effective water flow coverage during operation. This article is intended to give you an introduction to the various sprinkler heads used for irrigation. July 25th, 2019. VK345 - Microfast® Quick Response Upright Sprinkler (K5.6) - VdS, LPCB, FM Approved (Europe) Technical Data Sheet en zh VK350 - Microfast® Quick Response Upright Sprinkler (K8.0) These are used when sprinklers cannot be located in the ceiling. With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Model NV003/NV004 Upright and Model NV005/ NV006 Pendent Sprinklers are rated for use at a maximum service pressure of 175 psig (12 bar). Glass Bulb Fire Sprinkler, Fusible Alloy Fire Sprinkler, Esfr Fire Sprinkler manufacturer / supplier in China, offering T-Zstz 15 68 Degree Upright Vertical Fire Sprinkler, DN15 5mm Glass Ball Pendent Fire Sprinkler, 93 Degree Concealed Fire Sprinkler and so on. HD272 - QR, Upright DESCRIPTION Pendent & Upright Sprinklers HD Pendent and Upright Sprinklers are designed for use in light and ordinary hazards. Sprinkler Type “K” Factor Sprinkler Height Approvals Sprinkler Identification Number (SIN) US Metric SSU SSP Standard–Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position 5.62 4.24 2.82 1.98 7.96 8.20 8.20 Rs 500/ Piece Get Latest Price. Autocad work. A wide variety of upright type sprinkler options are available to you, such as type. Sprinkler orientation. They install deflector-up to cover specific areas and to prevent ice and debris from collecting in the head. Standard Response/Quick Response/ESFR Fire Sprinkler Heads, Pendent/Sidewall/Upright Type 売れ行き好調な商品 以下で売れ行き好調: UPRIGHT TYPE SPRINKLER HEAD. Side Wall Sprinkler Head. The Computer-Aided Design ("CAD") files and all associated content posted to this website are created, uploaded, managed and owned by third party users. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 SIN 570 5.6K UPRIGHT (1/2˝ NPT) TY315 571 5.6K PENDENT (1/2˝ NPT) TY325 SPRINKLER 3 This type of sprinkler head has deflectors that are curved down to spray the water in a hemispherical pattern. a sprinkler system or its compo-nents and cause the sprinkler to ail to operate in a fire situation or cause it to operate prematurely. without obstruction through the sprinkler and is distributed by the ture, the sprinkler opens which causes the release of the seat insert, allowing the inner tube and the ball stop to drop down, allowing the upright and dry pendent styles. These type of sprinklers are used in most of the fire fighting applications. Autocad work. Approvals and Listings vary by sprinkler and are identified in the bulletin for the applicable sprinkler. As a leader in the fire protection industry since 1920, Reliable has built a reputation for manufacturing the highest quality fire sprinklers and has assembled the industry’s most trusted distribution network and team of fire protection industry experts. Sidewall Sprinkler Heads: sidewall sprinkler heads protrude horizontally out of the wall parallel to the floor, rather than descending from the ceiling or mounted on a pipe pointing upward. Salah satu komponen sprinkler adalah head sprinkler. Sprinkler is an important part of wet-type auto spraying system. We are a leading manufacturer and supplier of different equipments used in fire fighting such as Upright Type Sprinkler. They are generally used in mechanical rooms or other inaccessible areas to provide better coverage between obstructions like beams or ducts. Get Quote Concealed Sprinkler. As an example, they may be efficiently used when connected to a wet type sprinkler system and extended into an unheated attic space. Ini saat kita mw serah trima gaes.. Jadi beberapa sprinkler di test random.. Dan ini salah satunya.. Head sprinkler : Viking Type : Upright 68° Part : VK 100 . Our main aim is to satisfy all the customers’ demands with all positive results and we are fully backed up with stable infrastructure and with all state of art equipments and efficient / motivated employees. Service Pressure                : 175 psi. Warehouse type sprinkler is designed for the special applications such as high level storage systems. These type of sprinklers are used in most of the fire fighting applications. These sprinklers are manufactured using high quality materials and the latest technology and are available at affordable prices. Alibaba.com offers 781 fire sprinkler upright type products. The forged frame is more streamlined and attractive than traditional China 68 Cslsius 3/4 Upright Type Fire Sprinkler, Find details about China Fire Sprinkler, Sprinkler from 68 Cslsius 3/4 Upright Type Fire Sprinkler - Quanzhou Sanxing Fire-Fighting Equipment Co., Ltd. We are manufacturing these fire hoses from last 7 years and exporting globally with all relevant / major certificates like UL, ULC, BSI, ISI, CE, TUV SUD. Chapters 10 through 15 of NFPA 13 (2019) provide these guidelines in detail. A second deflector also sprays water back toward the wall so that the wall is protected. Please rest assured to get the quality products made in China from our factory. NV003 UL Listed, Upright, Standard Response Type Sprinkler Head NV004 UL Listed, Upright, Quick Response Type Sprinkler Head NV006 UL Listed, Pendent, Quick Response Type Sprinkler Head They also provide a circle spray pattern while sprinkling the water and thus, covers all the area. Resource Number Downloads Collection FireLock™ Model FL-SR/DRY Upright, Pendent and Recessed Pendent Sprinklers K5.6 (8.1 SI), K8.0 (11.5 SI) Wholesale Trader of Palex Sprinkler - Upright Type Sprinkler, Side Wall Type Sprinkler, Gun Metal Fire Hose Delivery Coupling and Pendent Type Sprinkler offered … An upright-type fire protection sprinkler with a body defining an orifice and outlet for flow of fluid, and a deflector positioned coaxial with the outlet for impingement of fluid flow thereupon, has Required fields are marked *. The TYCO Series TY-L, 5.6 and 8.0 K-factor, side wall and Recessed Pendent Sprinklers described in this data sheet are stan - dard response, standard coverage, solder type spray sprinklers designed for use in light, ordinary, and extra hazard, commercial occupancies such as banks, hotels, shopping malls, fac - tories, refineries, chemical plants, etc The design and performance of fire sprinkler heads have a significant impact on distance and obstruction requirements. Address: A-56, Mangolpuri Industrial Area Phase II, Phase 2, Pocket A, Industrial Area, Mangolpuri S Block, Delhi, 110083, Temperature Rating                     : 155°F/68°C, Glass Bulb Color                         : Red, Thread Size                                 : NPTI/2″ Or R1/2″, Max. We are a leading manufacturer and supplier of different equipments used in fire fighting such as Upright Type Sprinkler. These type of sprinklers are used in most of the fire fighting applications. Worldwide Contacts www.tyco-˜re.com General Description The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprin … Reliable extended coverage sprinklers come in a wide array of configurations. China UL Certificate Fire Sprinkler Upright Type for Fire Fighting, Find details about China Sprinkler, Fire Sprinkler from UL Certificate Fire Sprinkler Upright Type for Fire Fighting - Shenzhen Asenware Test and Control Technology Co., Ltd. The Globe Quick Response GL Series Dry Type Upright Sprinkler is designed for use in special applications such as freezing environments. The email with your password reset link has been sent. Offered products are sourced from the trusted vendors of the market to render maximum client satisfaction Reliable We offer all the products in bulk quantity. Upright sprinkler heads point towards the ceiling. Upright sprinkler is suited for areas that are difficult to access, like beams, ducts, and buildings with exposed ceilings. It will help you choose the best sprinkler for your situation. Each CAD and any associated text, image or data is in no way sponsored by or affiliated with any company, organization or real-world item, product, or good it may purport to portray. The Globe Model J Dry Type Vertical Sidewall Sprinkler utilizes s frangible amt)ule sDrinkler. The forged frame is more streamlined and attractive Esfr Upright Type Fire Sprinkler picture from Fujian Haijing Fire-Fighting Co., Ltd. view photo of Chrome Finished Fire Sprinkler Head, Fire Sprinkler Head, Standard Response Fire Sprinkler.Contact China Suppliers for More Products and Price. The sprinkler heads that are not designed to retract into the earth when not in use can be thought of as having a “raised” elevation. Sprinkler characteristics. flameguard sprinkler fl100 – flameguard sprinkler fl200 – flameguard sprinkler – flameguard fl100 – flameguard fl200 – sprinkler – sprinklers. An upright-type fire protection sprinkler with a body defining an orifice and outlet for flow of fluid, and a deflector positioned coaxial with the outlet for impingement of fluid flow thereupon, has one or a combination of the following features for improved performance. ... Upright Type Fire Sprinkler Rs 100/Number. Finishing: Chrome. The MX8520 Minimax Early Suppression Fast Response (ESFR) Upright Sprinkler is a fast response fusible element type sprinkler designed for early fire suppression. The MX8520 Minimax Early Suppression Fast Response (ESFR) Upright Sprinkler is a fast response fusible element type sprinkler designed for early fire suppression. They are generally used in mechanical rooms or other inaccessible areas to provide better coverage between obstructions like beams or ducts. The sprinklers come with compact design, glass bulb type… Bulb Size: 1/2", 3/4" Temperature Rating: Standard. The sprinkler heads that are not designed to retract into the earth when not in use can be thought of as having a “raised” elevation. / Reference FOB Price 1,000-29,999 Pieces US $1.5 Quanzhou Sanxing Fire-Fighting Equipment Co., Ltd. … The forged frame is more streamlined and attractive Sprinkler system types Wet – Wet type systems are the most common type of sprinkler system that is installed. Buy low price Upright Type Sprinkler in BORIVALI (W), Mumbai. July 25th, 2019. TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan - dard Response (5 mm bulb), Standard Coverage Dry-type Sprinklers are dec - orative glass bulb automatic sprinklers typically used where: • pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (for exam- ple, sprinkler drops from unheated portions of buildings) • sprinklers and/or a portion of the … Upright type, design incorporates state-of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, precise operation. Upright fire sprinklers spray water upward to a concave deflector, producing a dome-shaped spray pattern. Temperature Range: As per standards. Sprinkler Type: Standard. Find upright and side type sprinkler for ceiling 68 degree from PRI-SAFETY here at chinafiresafety.com. An upright-type fire protection sprinkler with a body defining an orifice and outlet for flow of fluid, and a deflector positioned coaxial with the outlet for impingement of fluid flow thereupon, has one or a combination of the following features for improved performance. The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described in herein are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers. Penempatan Sprinkler Pendent dan Sprinkler Upright yang benar. fireproect | sprinkler | sprinkler upright | sprinkler pendent | flush type sprinklers -flush type – Flush Type Sprinklers Quick – Flush Type Sprinklers Standard – sprinklers pendent – sprinklers upright – sprinkler fl100p – sprinkler fl100u – sprinkler fl200p – sprinkler fl200u – sprinkler fl100 – sprinkler fl200 An additional benefit to upright sprinkler heads is that since the deflector covers over the sprinkler head, it also protects it from debris and ice collecting. sprinkler sprinkler upright sprinkler pendent flush type sprinkler flush type glass bulb sprinkler glass bulb sprinkler pendent glass bulb sprinkler upright. About 0% of these are Garden Sprinklers. 68˚ C Upright Type Glass Bulb Fire Sprinkler Get Latest Price Purchase Qty. For example, a head that you Your email address will not be published. At the same time it will warn you away from some common and costly errors often made in sprinkler head selection. Alibaba.com offers 1,735 upright type sprinkler products. Worldwide Contacts www.tyco-˜re.com General Description TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan - dard Response (5 mm bulb), Standard Coverage Dry-type Sprinklers are dec - Upright sprinkler heads project up into a space and have deflectors that spray the water downwards. Di bawah ini akan kami sajikan type-type sprinkler yang biasa digunakan dalam instalasi sprinkler di gedung , antara lain : China 68˚ C Upright Type Glass Bulb Fire Sprinkler, Find details about China Fire Sprinkler, Fire Fighting from 68˚ C Upright Type Glass Bulb Fire Sprinkler - Quanzhou Sanxing Fire-Fighting Equipment Co., Ltd. Upright sprinkler heads project up into a space and have deflectors that spray the water downwards. As one of the leading manufacturers and suppliers in China, we have passed CE, EN3, LPCB, EN671, UL and MED If you don't receive the email within an hour (and you've checked your Spam folder), email us as confirmation@grabcad.com. Upright Type Sprinkler offered by PALLADIUM SAFETY SOLUTION P. LTD. is available with multiple payment options and easy delivery. NOT TO BE USED FOR INSTALLATION PURPOSES. Upright sprinklers are installed where obstructions interfere with coverage and in dry-pipe systems facing freezing temperatures. Dry-type Sprinkler at standard response with 5 mm glass bulb has pendent, upright, and horizontal sidewall types. Sprinkler akan secara otomatis menyala bila ada kebakaran yang terjadi. Weight: 50 grams. Privacy Policy | Disclaimer | Terms & Condition, Chawla Hose Manufacturing Co. ” is the leading manufacturers & exporters of fire fighting hoses from size 38mm to 70mm dia. Upright type, design incorporates state-of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, precise operation. We “ Chawla Hose Manufacturing Co. ” is the leading manufacturers & exporters of fire fighting hoses from size 38mm to 70mm dia. Pendent Upright Sidewall Type of Fire Sprinkler 1. SPRINKLER HEAD Upright, Pendent & Recessed Pendent Sprinklers Sprinkler Identification Number Standard SD1015, SD1010 (bulb 5mm), Quick Response SD1030, SD1032 (bulb 3mm) Style Upright Sprinkler SD1015, ½½) The forged frame is more streamlined and attractive than traditional a sprinkler system or its compo-nents and cause the sprinkler to ail to operate in a fire situation or cause it to operate prematurely. These type of sprinklers gives the more water with more … Fire sprinkler is fitted at the end of pipeline to spray water for extinguishing or suppressing the fire. UPRIGHT TYPE SPRINKLER HEAD. A wet pipe system has water in the pipes in the ambient or normal condition and has heat responsive elements on all A wide variety of upright type sprinkler options are available to you, such as type. An upright sprinkler is installed at the top with an upper water deflector, so water coming out of the orifice shoots upward. As one of the leading manufacturers and suppliers in China, we have passed CE, EN3, LPCB, EN671, UL and MED certification. Torque sprinklers 7 to 14 ft.-lbs. Be the first to review “UPRIGHT TYPE SPRINKLER”. China Esfr Upright Type Fire Sprinkler, Find details about China Chrome Finished Fire Sprinkler Head, Fire Sprinkler Head from Esfr Upright Type Fire Sprinkler - Fujian Haijing Fire-Fighting Co., Ltd. UPRIGHT SPRINKLER STANDARD RESPONSE - 1/2" - 3/4" BIMobject® Corporation, acknowledged by investors with a Global Red Herring 100 award, and a public company on NASDAQ OMX: ticker BIM. These are highly reckoned among our clients due to their superior finishing and reliability. Find upright and side type sprinkler for ceiling 68 degree from PRI-SAFETY here at chinafiresafety.com.